NewNumberForEISDC
Back to current versionRestore this version

The datasets for EIS Data Compression (DC) factor investigation are chosen as follows:

1. search EIS study database(info) to find out which study has adotped a specific compression scheme such as DPCM, JPEG95, etc. For example, study 29, 30, 31, 32, 91, 92, 142, 255, 258 have ever used JPEG90 compression scheme.

notes:


2. Once knowing details (eg. ID) of rasters, which using a specific compression scheme, one can extract oringinal data volume for these rasters (through EIS planning database), and the corresponding fits files (through EIS science database), then work out the data set for the investigation. The file datasets_list.txt(info) lists the datesets used in this case.

notes:




The way to calculate EIS onboard compressed data volume with MDP status curves was descirbed in previous post abut EIS DC factor: check it here.

The following links show DC factor variation in different scenarioes (eg. AR, QS for SCI_OBJ, 1", 2", 40", and 266" for SLA).

A conservative estimation of avgerage factor is indicated by orange dash-line on the plot, which could be used to improve EIS planning tools when the number will be approved/corss-checked.



note:

EIS Data Compression (DC) factors listed here are only for Science Target & Slit/Slot selection. For factor varation upon exposure time, please refer H. Hara's results, (PDF(info))




For easy analysis a data table can be worked out as follows, using the plots shown in above links:


Scheme Total QS AR CH 1" 2" 40" 266"
DPCM 2.19 (2.38)2.192.192.542.462.192.18
JPEG98 2.462.223.152.85 (avg)2.312.28 (2.32)
JPEG95 3.643.26 6.126.38 (6.54)3.26
JPEG92 3.316.65 (avg)2.746.53 (avg)2.743.63
JPEG90 3.824.343.734.67 (avg) 3.843.78
JPEG85 4.824.514.913.9 (avg) 4.51
JPEG75 6.2 18.88 (avg) 6.27.52
JPEG65 19.94 (avg) 25.97 (avg) 7.33 (avg)
JPEG50 20.9817.72 35.37 (avg) 17.72